Fitting Protective Equipment
- Pull the plug out of the socket before carrying out any work on the power tool.
Note: If the grinding disc breaks during operation or the holding fixtures on the protective guard/power tool become damaged, the power tool must be sent to the after-sales service immediately; see the "After-Sales Service and Application Service" section for addresses.
Place the protective guard (6) on the spindle collar. Adjust the position of the protective guard (6) to meet the requirements of the operation. Lock the protective guard (6) by tightening the locking screw (7) using the combination wrench (4).
- Adjust the protective guard (6) such that sparking in the direction of the operator is prevented.
Note: The coding cams on the protective guard (6) ensure that only a protective guard that is suitable for the power tool can be fitted.
Screw the auxiliary handle (3) on the right or left of the machine head depending on the working method.
The low-vibration auxiliary handle reduces vibration, enabling the tool to be used safely and more comfortably.
- Do not operate your power tool without the side handle (3).
- Do not make any alterations of any kind to the auxiliary handle.
Do not continue to use a damaged auxiliary handle.