Technical data
Digital laser measure | GLM 100-25 C |
---|---|
Article number | 3 601 K72 Y.. |
Measuring rangeA) | 0.08–100 m |
Measuring range (unfavourable conditions)B) | 0.08–60 m |
Measuring accuracyA) | ±1.5 mm |
Measuring accuracy (unfavourable conditions)B) | ±3.0 mm |
Smallest display unit | 0.5 mm |
Indirect distance measurement and spirit level | |
Measuring range | 0°–360° (4 × 90°) |
Grade measurement | |
Measuring range | 0°–360° (4 × 90°) |
Measuring accuracyC)D) | ±0.2° |
Smallest display unit | 0.1° |
General | |
Operating temperatureE) | –10 °C to +45 °C |
Storage temperature | –20 °C to +70 °C |
Relative air humidity max. | 90 % |
Max. altitude | 2000 m |
Pollution degree according to IEC 61010-1 | 2F) |
Laser class | 2 |
Laser type | 650 nm, < 1 mW |
Divergence of the laser beam | < 1.5 mrad (full angle) |
Automatic switch-off after approx. | |
| 20 s |
| 5 min |
Non-rechargeable batteries | 3 × 1.5 V LR6 (AA) |
Weight according to EPTA-Procedure 01:2014 | 0.23 kg |
Protection rating | IP 54 (dust and splash-proof) |
Dimensions | 142 (176) × 64 × 28 mm |
Data transmission | |
Bluetooth® | Bluetooth® 4.2 |
Operating frequency range | 2402–2480 MHz |
Max. transmission power | 8 mW |
- A)
When measuring from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 25 °C operating temperature; a distance-dependent deviation of ±0.05 mm/m must additionally be factored in.
- B)
When measuring from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), strong background lighting, 25 °C operating temperature and large altitudes. In addition, a deviation of ±0.15 mm/m must be taken into account, depending on the distance.
- C)
At an operating temperature of 25 °C
- D)
After user calibration at 0° and 90°; An additional grade error of ±0.01°/degree to 45° (max.) has to be taken into account. The left-hand side of the measuring tool serves as the reference level for grade measurement.
- E)
In continuous measurement mode, the max. operating temperature is +40 °C.
- F)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
- G)
When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system. Bluetooth® tools must support the GATT profile.
The serial number (16) on the type plate is used to clearly identify your measuring tool.